LG CH23 Error, What Low DC Link Voltage Really Means
Before power reaches the compressor, the LG inverter board converts household electricity into a steady internal supply called the DC link.
When that internal voltage sags below a safe level, the board stops the compressor and the indoor display shows the LG CH23 error. The cause may sit in your home wiring, the board or the components that smooth the supply. This page explains each possibility in plain terms.
What does CH23 stand for?
LG service documents generally describe CH23 as a DC link low voltage error. Inside the condenser unit, incoming alternating current passes through a rectifier, which turns it into direct current. Large capacitors then smooth that direct current into a stable reservoir of energy. This reservoir is the DC link. The power module draws from it to create the variable supply that drives the compressor.
The board monitors the DC link voltage continuously. If it falls below a set threshold, the power module cannot drive the compressor properly. To prevent erratic operation or damage, the board halts the compressor and reports CH23.
Why does the DC link voltage matter?
Think of the DC link as a water tank feeding a pump. If the tank level drops too low, the pump draws air and struggles. Similarly, when the DC link voltage drops, the power module cannot deliver enough energy to the compressor windings. The compressor may lose speed, stall or draw abnormal current. Low link voltage also affects the stability of other circuits on the board.
By stopping early, the board protects the compressor and power module from running in a weak, unstable state.
What symptoms accompany CH23?
The code usually appears alongside a few telltale signs.
- The condenser unit starts, then stops after a short time.
- Lights in the home dim when the air conditioner starts.
- The fault appears at busy times of day when household demand is high.
- Breakers or safety switches occasionally trip.
- The code appeared after a storm or electrical work.
- The system works on some days and fails on others without obvious reason.
These clues help a technician decide whether to focus on supply, board or capacitors.
What usually causes low DC link voltage?
Low incoming supply voltage
If the supply at the condenser unit is weak, the DC link cannot reach its normal level. Causes include long or undersized cable runs, loose connections at the switchboard or isolator, a failing breaker and local network issues. Supply problems often get worse under heavy load, such as when ovens, heaters and air conditioners run together.
Ageing smoothing capacitors
The large capacitors on the inverter board lose capacity as they age, particularly in hot environments. Weak capacitors cannot hold the DC link steady under load, so voltage dips when the compressor demands energy.
Rectifier or input stage faults
The rectifier and related components convert incoming power. If one part fails or degrades, the conversion becomes inefficient and the DC link voltage drops.
Power factor correction problems
Many LG inverter boards include a power factor correction stage that boosts and stabilises the DC link. If that stage fails, link voltage may fall below normal. LG reports PFC faults separately with CH27 on many models, but the two can appear together.
Loose or damaged wiring
Loose terminals at the isolator, inside the condenser unit or on the board create resistance. Under load, voltage drops across those connections, starving the DC link.
Faulty voltage sensing
Occasionally, the circuit that measures the DC link on the board fails and reports a low reading that is not real.
What can you check safely?
Electrical faults need a qualified technician or electrician, but a few observations help.
- Note whether lights dim when the condenser unit starts.
- Check whether the air conditioner circuit breaker has tripped and reset it once if safe.
- Observe whether CH23 appears mainly when other large appliances run.
- Look at the isolator switch for signs of heat, such as discolouration, without touching it.
- Restart the system once after a few minutes with power off.
If CH23 returns, leave the system off and book a visit. Our LG reset guide explains the safe restart steps. Never open the isolator or condenser unit yourself.
How does a technician diagnose CH23?
The technician begins with the supply. They measure voltage at the isolator with the system off, then again while the compressor starts and runs. A significant drop under load points to supply problems, which may need a licensed electrician.
Next, they inspect all connections from the isolator to the board for tightness and heat damage. Then, after discharging the board safely, they examine the capacitors for swelling, leakage or other signs of failure, and may test their capacitance.
They also check the DC link voltage directly while running, comparing it with the board reading. If the real voltage is normal but the board reports low, the sensing circuit is faulty. If the real voltage is low despite a good supply, the problem lies in the rectifier, PFC stage or capacitors.
Which repairs typically clear CH23?
| Finding | Typical repair |
|---|---|
| Weak supply under load | Licensed electrician repairs cabling or connections |
| Loose or burnt terminals | Repair terminals and wiring |
| Aged smoothing capacitors | Replace capacitors or the outdoor board |
| Rectifier or PFC fault | Replace the outdoor board |
| Faulty voltage sensing | Replace the outdoor board |
After repair, the technician monitors DC link voltage and supply voltage under load to confirm stability.
Why does CH23 often appear at peak times?
Household and street demand varies throughout the day. Early evening in summer often brings the heaviest load, as people return home and switch on air conditioners, ovens and other appliances at once. Supply voltage can sag a little during these periods. A system with marginal wiring or tired capacitors may cope at quiet times but fail at peak. If CH23 appears mainly in the late afternoon or evening, mention that pattern.
Can storms trigger CH23?
Yes. A surge can damage the rectifier, the PFC stage or the capacitors, leaving the DC link unable to hold its voltage. Storms can also cause brief supply dips that trip the protection without leaving damage. If a reset clears the code after a storm and it does not return, the event was likely temporary. If it persists, damage is more likely.
How does CH23 relate to CH27?
CH27 typically reports a power factor correction fault. Because the PFC stage helps maintain the DC link, a PFC failure often drags the link voltage down too. The two codes can appear together or one after the other. Our LG CH27 error page explains PFC faults in more detail.
Why do capacitors age faster in hot locations?
Electrolytic capacitors contain a liquid electrolyte that slowly dries out over time. Heat speeds that process dramatically. A condenser unit facing the afternoon sun, crammed into a narrow passage or covered in dust runs hotter inside, which shortens capacitor life. Shade that leaves airflow clear and a clean heat sink help the board stay cooler. Our LG outdoor unit check guide covers placement basics.
How does the electrician fit into the repair?
If testing points to the supply, such as undersized cable, a failing breaker or loose switchboard connections, a licensed electrician must carry out that work. The air conditioning technician can identify the issue and explain it, then the electrician corrects it. Sometimes both trades work together to confirm the system runs normally afterwards.
Is CH23 expensive?
It varies. Tightening a loose connection is quick. Supply upgrades depend on the work needed. Board replacement costs more but is still far less than a compressor. Our LG AC repair cost Sydney page outlines cost factors.
What should you tell the technician?
Share the model number from the indoor head label, when CH23 appears, whether lights dim, whether other appliances were running and any recent storms or electrical work. If your home has had other electrical issues, mention those too.
How can you stay comfortable meanwhile?
Leave the system off once CH23 repeats. In summer, use fans and blinds and avoid running many large appliances at once. In winter, use a safe portable heater.
Could solar or other equipment affect CH23?
Some homes have solar inverters, batteries or other large equipment connected to the same switchboard. Generally, these systems work well alongside air conditioners. However, faults in shared wiring or connections can affect voltage at the condenser unit. If your home has recently had solar or battery equipment installed, mention it. A technician or electrician can check whether any changes affected the air conditioner circuit.
Does CH23 mean the outdoor board is finished?
Not necessarily. Many CH23 cases trace back to the supply or a loose connection, both of which are simpler fixes than a board. Even when the board is at fault, replacing it usually restores full operation without touching the compressor or refrigerant. A careful technician will confirm the cause before recommending any part.
How can you reduce the risk of CH23?
- Ask an electrician to check the air conditioner circuit if lights often dim.
- Keep the condenser unit shaded without blocking airflow.
- Keep the outdoor coil and surroundings clean so the board runs cooler.
- Consider surge protection advice from a licensed electrician.
- Book regular servicing so a technician can inspect the connections.
How does the board behave as voltage sags?
LG inverter boards do not simply switch off at the first dip. As DC link voltage falls, the board often reduces compressor speed first, trying to lower demand and keep running. You might notice weaker cooling or heating for a while before the code appears. If voltage keeps dropping despite that reduction, the board finally stops the compressor and shows CH23.
This staged response explains why some owners report that the system felt sluggish for a few minutes before shutting down. Mentioning that observation helps the technician recognise a supply or capacitor issue rather than a refrigerant problem.
What does a swollen capacitor look like?
Capacitors on the inverter board are usually cylindrical with a vented top. A healthy one has a flat top. A failing one may bulge, show a raised dome or leak a brown residue around its base. These signs are only visible once the cover is off, so this is strictly a technician task. Still, it is a common finding on boards from condenser units that sit in full sun for many years.
When the technician finds swollen capacitors, they consider whether to replace the whole board or, where practical and supported, the capacitors alone. Board replacement is often preferred because other components nearby may also have aged.
Can extension of the cable run cause problems?
Yes. When a condenser unit moves further from the switchboard, perhaps during renovations, the supply cable may get extended. If the new run uses thinner cable or a joint sits in a damp spot, voltage drop increases. The system may have worked perfectly before the change and then begin showing CH23. A licensed electrician can confirm whether the cable size suits the new length and load.
Does CH23 affect multi split systems differently?
On a multi split, a single condenser unit serves several rooms, so CH23 stops every indoor head at once. Because these units often draw more current, they are slightly more sensitive to weak supply. The diagnosis follows the same path, but supply checks under full load are especially important.
How quickly can it be fixed?
Connection repairs and simple supply fixes often happen on the first visit. Board replacements depend on part availability for your model, which the technician will confirm before ordering.
LG CH23 error, booking help
The LG CH23 error tells you the internal power reservoir in the condenser unit is running low. With careful testing of the supply, connections and board, a technician can find the weak link and restore stable power.
Call 02 9071 1142 or use our booking page to arrange an LG technician.
Frequently asked questions
What does CH23 mean on an LG?
It generally indicates low DC link voltage in the outdoor inverter board.
Can a weak power supply cause CH23?
Yes. Low supply voltage is a common cause.
Why do my lights dim when the air conditioner starts?
It can point to a supply or connection problem worth checking.
Is CH23 related to CH27?
Often. A PFC fault can pull the DC link voltage down.
Can I fix CH23 myself?
No. It involves high voltage parts and possibly supply wiring.
Does CH23 mean a new compressor?
Rarely. Supply, wiring and board faults are more common.