LG CH45 Error, Trouble With the Condenser Coil Probe

Tucked against a copper bend on the outdoor coil sits a probe that tells your LG how that coil is coping.

In summer it warns of overheating, and in winter it decides when frost has melted. If the board gets a nonsense value from it, the system stops with the LG CH45 error. Below, we look at real world scenarios, likely causes and how the problem gets resolved.

What is the LG CH45 error?

LG service information usually describes CH45 as a condenser pipe temperature sensor fault, sometimes labelled the outdoor coil or outdoor pipe thermistor. The probe clips onto a tube in the outdoor coil and reports its temperature to the outdoor board. If the board reads a value that suggests an open circuit, a short or a temperature the coil could never reach, it stops the system and shows CH45.

This probe measures the coil itself rather than the air around it. That distinction matters, because the coil temperature tells the board how the refrigerant inside is behaving.

Why does the coil temperature matter so much?

The outdoor coil changes roles depending on the mode. In cooling, it acts as the condenser, releasing heat from the house into outdoor air. Its temperature closely tracks the condensing pressure, so the board uses it as an early warning of excessive pressure. In heating, the coil becomes the evaporator, pulling warmth from outdoor air. Its temperature then drops below the air temperature and often below freezing, which leads to frost.

The coil probe lets the board respond correctly in both cases. Without it, the system could overheat in summer or bury the coil in ice in winter.

Scenario one, a frosty winter morning

Imagine a cold, damp July morning in a western suburb. Your LG has been heating since dawn. Frost slowly forms on the outdoor coil as moisture freezes on the fins. The board watches the coil probe and the outdoor air probe together. When the coil gets cold enough for long enough, the board starts a defrost cycle, reversing the refrigerant flow to warm the coil.

During defrost, the coil probe tells the board when the ice has melted. Once the coil reaches a set temperature, defrost ends and heating resumes. If the probe fails or reads wrongly, defrost might end too early, leaving ice behind, or run too long, wasting energy and leaving the room cold. A clear sign is a system that defrosts constantly or one that builds heavy ice despite defrosting.

Scenario two, a scorching summer afternoon

Now picture a hot January afternoon. The condenser unit works hard to dump heat into air that is already very warm. The coil temperature rises with condensing pressure. If the coil probe reports a value close to the protective limit, the board slows the compressor or speeds up the outdoor fan to bring pressure down.

Should the probe read too low, the board may not protect the system early enough. If it reads too high, the board may throttle the compressor unnecessarily, leaving you uncomfortable. In either case, if the reading becomes impossible, CH45 stops the system altogether.

Which symptoms point to a coil probe fault?

Owners often notice one or more of these before or alongside CH45.

  • Frequent, long or unusual defrost cycles in winter.
  • Heavy ice on the outdoor coil that never seems to clear.
  • Weak cooling on hot days with the condenser unit running hard.
  • Outdoor fan speed that seems wrong for the weather.
  • The code appears after rain, a storm or pest activity.
  • The fault comes and goes with the weather.

What usually causes CH45?

A failed probe

Outdoor coil probes face constant temperature swings, from icy defrost conditions to scorching summer heat. Moisture and salt can work into the probe body. Eventually, the reading becomes inaccurate or the circuit fails.

A lead damaged by weather or pests

The lead runs along the coil and through the cabinet. Ultraviolet light, sharp fins, vibration and chewing animals can all damage it.

A corroded plug

The connector on the outdoor board sits in a damp, often salty environment. Corrosion builds up over time and disturbs the reading.

A probe slipped from its clip

Vibration or careless cleaning can dislodge the probe. Once it no longer touches the tube firmly, it reads air temperature instead of coil temperature.

A board input fault

Occasionally, the circuit on the outdoor board that reads the probe fails.

What can you check safely?

Only a technician should open the condenser unit, yet you can observe a few things safely.

  • Switch off at the remote and outdoor isolator.
  • Look for heavy ice on the coil in winter and allow it to melt fully.
  • Check around the condenser unit for damaged cables or nesting material, without touching anything.
  • Clear leaves and debris from around the cabinet.
  • Restore power and restart once.

If CH45 returns, leave the system off and book a visit. Our LG reset guide explains the safe restart steps.

How does a technician test the coil probe?

After isolating power, the technician removes the access panel and locates the probe on the coil. They check how firmly it sits in its clip and inspect the lead for damage.

Then they disconnect the probe and measure its resistance, comparing the result with LG published values for the measured coil temperature. A clamp thermometer on the same tube gives the reference figure. If the probe reads far off, open or short, it needs replacing.

If the probe tests well, they inspect the connector, then check the board input. Sometimes they also review how the system behaves through a diagnostic mode, comparing the board reading with the real tube temperature while the system runs.

Which repairs usually fix CH45?

FindingTypical repair
Faulty probeReplace the condenser pipe sensor
Probe loose on the tubeRefit with good thermal contact
Damaged leadRepair or replace and secure the lead
Corroded plugClean or replace the connector
Faulty board inputRepair or replace the outdoor board

After the repair, the technician checks readings in both cooling and heating where possible, and may force a defrost cycle to confirm it starts and ends correctly.

How is CH45 different from CH44?

CH44 concerns the outdoor air probe, which reads the air entering the condenser unit. CH45 concerns the coil probe, which reads the temperature of the coil tube itself. The board compares the two to judge frost conditions and system performance. Our LG CH44 error page explains the air probe.

How does CH45 relate to CH61?

CH61 generally reports condenser overheat, meaning the coil temperature itself has risen too high. In that case, the probe is working and reporting a genuine problem, often poor airflow or high pressure. CH45, in contrast, reports a probe fault rather than a real temperature. Our LG CH61 error page explains the overheat code.

Why do coastal and leafy homes see more CH45 faults?

Coastal air brings salt that corrodes probes, leads and plugs. Leafy suburbs bring debris that traps moisture against the coil and attracts nesting animals. Both environments shorten sensor life. Regular servicing, coil washing and a tidy area around the condenser unit help.

Is CH45 expensive to repair?

Usually not. The probe is a modest part and swapping it often takes little time. Costs rise if the board needs replacing or if the lead runs through hard to reach areas. Our LG AC repair cost Sydney page explains general cost factors.

What details help the technician?

Share the model number from the indoor head label, when CH45 first appeared, any defrost or ice problems, recent weather and any signs of pests. Photos of the outdoor coil, especially if iced, are very helpful.

How can you stay comfortable while waiting?

Leave the system off once CH45 repeats. Use fans and blinds in summer or a safe portable heater in winter.

How can you protect the coil probe?

  • Keep the condenser unit free of leaves and nesting material.
  • Rinse the coil gently only with power off, avoiding the electrical area.
  • Deal with pests around the house promptly.
  • Book regular servicing so a technician can check probe fit and readings.

Our LG air conditioner service Sydney page explains what a service includes.

Scenario three, an autumn storm

Consider a wet, windy evening in April. Rain lashes the back of the house and leaves pile against the condenser unit. Overnight, water finds its way past a cracked cable gland into the electrical compartment. By morning, the coil probe connector is damp and its reading jumps around. The board sees values that make no sense and shows CH45.

In this situation, the probe itself might be perfectly healthy. Drying and cleaning the connector, replacing the damaged gland and protecting the lead may be enough. That is why technicians inspect connectors and cable entries carefully before ordering a new sensor. Mentioning the storm when you book points them in the right direction from the start.

Scenario four, after a coil clean

Sometimes CH45 appears soon after someone cleaned the outdoor coil. Strong water jets or chemical cleaners can push moisture into the probe holder, loosen the clip or damage the lead insulation. The system may run fine for a day or two, then fail as corrosion takes hold or the probe slips further from the tube.

If this sounds familiar, let the technician know when the cleaning happened and who did it. They will check the probe fit, dry and clean the connector and replace the probe only if testing shows it has failed.

How does the probe help during defrost recovery?

After defrost finishes, the system needs to switch back to heating smoothly. The board watches the coil probe as the coil cools again and the indoor coil warms up. That timing affects how quickly warm air returns to the room. A drifting probe can cause a longer pause than normal, which owners sometimes describe as the system going cold for too long every hour or so. Our LG air conditioner not heating guide explains normal defrost behaviour.

Does a multi split behave differently?

A multi split has one condenser unit and usually one coil probe outside, so CH45 affects every room at once. The diagnosis follows the same steps. Because multi split coils are larger, technicians sometimes find the probe in a less accessible position, which can add a little time to the repair.

What does good probe placement look like?

LG positions the coil probe on a specific tube chosen to represent the coil temperature accurately. The probe usually sits in a small clip or pocket, often with a spring that keeps it pressed against the copper. Some technicians add thermal paste to improve contact. When a probe sits loosely or on the wrong tube, the board receives misleading values even though the probe works perfectly.

During any repair, the technician makes sure the probe returns to its original position, presses firmly against the tube and has its lead secured away from sharp fins and hot parts. That small detail prevents many repeat faults and keeps defrost and pressure control accurate for years.

LG CH45 error, booking help

The LG CH45 error means the outdoor board cannot trust its coil temperature reading. A technician can test the probe and its wiring, replace what has failed and restore accurate defrost and pressure control.

A reliable system starts with clean filters and clear airflow.

Reporting unusual behaviour early often keeps repair costs modest.

Clear access and good lighting help the technician work carefully.

If the fault seems linked to the weather, mention that pattern when you call.

Call 02 9071 1142 or use our booking page to arrange an LG technician.

Frequently asked questions

What does CH45 mean on an LG?

It generally points to a fault in the condenser pipe temperature sensor.

Can CH45 affect defrost?

Yes. The coil probe helps decide when defrost should end.

Why is my outdoor coil covered in ice?

Defrost problems, including a faulty coil probe, can cause heavy ice.

Is CH45 the same as CH61?

No. CH45 is a probe fault, while CH61 reports genuine condenser overheating.

Can pests cause CH45?

Yes. Chewed leads are a known cause.

Is the repair quick?

Usually. Replacing a coil probe is a common job.

{“@context”:”https://schema.org”,”@type”:”HVACBusiness”,”@id”:”https://lg.sydneyaircare.com.au/#business”,”name”:”Sydney Air Care, LG Service”,”url”:”https://lg.sydneyaircare.com.au/”,”description”:”LG air conditioner repair, service and troubleshooting across Sydney. Independent service provider, not affiliated with LG.”,”areaServed”:[{“@type”:”City”,”name”:”Sydney”},{“@type”:”State”,”name”:”New South Wales”}],”parentOrganization”:{“@type”:”Organization”,”name”:”Sydney Air Care”,”url”:”https://sydneyaircare.com.au/”},”telephone”:”+61 2 9071 1142″} {“@context”:”https://schema.org”,”@type”:”FAQPage”,”mainEntity”:[{“@type”:”Question”,”name”:”What does CH45 mean on an LG?”,”acceptedAnswer”:{“@type”:”Answer”,”text”:”It generally points to a fault in the condenser pipe temperature sensor.”}},{“@type”:”Question”,”name”:”Can CH45 affect defrost?”,”acceptedAnswer”:{“@type”:”Answer”,”text”:”Yes. The coil probe helps decide when defrost should end.”}},{“@type”:”Question”,”name”:”Why is my outdoor coil covered in ice?”,”acceptedAnswer”:{“@type”:”Answer”,”text”:”Defrost problems, including a faulty coil probe, can cause heavy ice.”}},{“@type”:”Question”,”name”:”Is CH45 the same as CH61?”,”acceptedAnswer”:{“@type”:”Answer”,”text”:”No. CH45 is a probe fault, while CH61 reports genuine condenser overheating.”}},{“@type”:”Question”,”name”:”Can pests cause CH45?”,”acceptedAnswer”:{“@type”:”Answer”,”text”:”Yes. Chewed leads are a known cause.”}},{“@type”:”Question”,”name”:”Is the repair quick?”,”acceptedAnswer”:{“@type”:”Answer”,”text”:”Usually. Replacing a coil probe is a common job.”}}]}