LG CH27 Error, A Fault in the Power Factor Correction Stage
Modern LG condenser units include a clever circuit that tidies up how they draw power from the grid.
It is called power factor correction, and it also helps keep the internal supply steady. When that circuit misbehaves, the board stops the compressor and shows the LG CH27 error. This guide explains the idea behind PFC in simple language, the common causes of failure and how a technician handles the repair.
What does CH27 mean on an LG?
LG service information typically describes CH27 as a PFC fault or AC input instant overcurrent related to the power factor correction circuit. The PFC stage sits between the incoming household supply and the DC link on the outdoor inverter board. It shapes the current drawn from the grid so it follows the voltage waveform smoothly, and it often boosts the DC link to a higher, stable level.
When the board detects abnormal current or voltage in that stage, it shuts the compressor down to protect components and records CH27.
What is power factor correction in plain terms?
Imagine pouring water into a bucket from a jug. If you pour smoothly, little spills. If you pour in sudden splashes, water goes everywhere and you need a bigger jug to fill the same bucket. Electrical devices that draw current in short, sharp bursts behave like the splashy pour. They create waste in the network and need heavier wiring for the same work.
A PFC circuit makes the inverter draw current smoothly, like the steady pour. It uses a fast switching transistor, an inductor and control electronics to shape the current. As a bonus, it can lift the DC link voltage, giving the compressor drive more headroom.
What symptoms often appear with CH27?
The code can arrive suddenly, yet some patterns show up again and again.
- The condenser unit starts briefly and then stops.
- A buzz or whine comes from the outdoor unit just before the stop.
- Breakers or safety switches trip occasionally.
- The fault follows a storm, blackout or electrical work nearby.
- CH23 or CH21 also appeared at some point.
- The problem occurs more in very hot weather.
Each clue helps narrow the cause, so note what you notice.
What usually causes a PFC fault?
A failed switching transistor
The PFC transistor switches many thousands of times per second. Heat, surges and age can damage it, causing shorts or erratic switching that trip the protection.
A failing inductor or reactor
Many LG condenser units use a large coil called a reactor or inductor as part of the PFC stage. It may sit on the board or as a separate component in the cabinet. Damaged windings, loose connections or overheating can disrupt it.
Supply disturbances
Surges, brief outages and unstable voltage can upset the PFC control and trip CH27. If the disturbance damaged components, the code persists after a reset.
Loose or burnt connections
The PFC stage carries significant current. Loose terminals on the reactor leads or board connectors heat up and create intermittent faults.
Board component ageing
Capacitors, diodes and control chips near the PFC stage age with heat. Over time, they may drift out of tolerance and cause instability.
Moisture or pests
Water ingress and insects inside the outdoor cabinet can cause leakage currents or short circuits around high voltage components.
What can owners safely do?
There are no repairs an owner should attempt on PFC circuits, but a few steps are safe.
- Switch the system off at the remote and at the circuit breaker.
- Wait several minutes before restoring power.
- Check that the condenser unit is free of visible water damage or insect activity from the outside.
- Restart once and observe the condenser unit from a safe distance.
- Note any buzzing, clicking or smells.
If CH27 returns, leave the system off and book a visit. Our LG reset guide explains a safe power cycle. Do not open the condenser unit, as high voltages remain after power is off.
How does a technician diagnose CH27?
The technician first confirms the supply is stable at the condenser unit, both at rest and under load. Then they isolate power, discharge the board safely and inspect the PFC area. They look for burnt components, swollen capacitors, cracked solder joints, insect debris and moisture.
Next, they check the reactor or inductor and its connections. Resistance tests reveal open or shorted windings, while visual checks show overheating or loose terminals.
They also test the PFC transistor and diodes with a meter. A shorted component usually confirms the fault. In some cases, problems only show under load, so they may monitor DC link voltage and input current while running the system.
Which repairs usually clear CH27?
| Finding | Typical repair |
|---|---|
| Damaged PFC components | Replace the outdoor inverter board |
| Faulty reactor or inductor | Replace the reactor and check connections |
| Loose or burnt connections | Repair terminals and wiring |
| Supply problem | Licensed electrician repairs the supply |
| Moisture or pest damage | Clean, dry, seal and repair affected parts |
After the repair, the technician monitors DC link voltage and input current to confirm smooth, stable operation.
Why do PFC circuits fail?
Heat is the main enemy. PFC components handle significant energy, and they rely on heat sinks and airflow inside the condenser unit to stay cool. When the unit sits in full sun, the coil is dirty or the fan is weak, internal temperatures rise. Over years, that heat ages semiconductors and capacitors.
Surges add another risk. Lightning or grid switching can send spikes straight into the input stage, which is the first part of the board to meet incoming power. The PFC stage therefore takes much of the hit.
How does CH27 relate to CH23?
The PFC stage helps maintain DC link voltage. If PFC fails, link voltage often drops, so CH23 may appear as well. Conversely, a fault that drags the DC link down can stress the PFC stage. The two codes are closely linked, and technicians often investigate them together. Our LG CH23 error page explains low DC link voltage.
Can a reactor fail without warning?
Reactors are robust, yet they can fail. Connections can loosen from vibration, and the windings can overheat if airflow inside the cabinet is poor. Sometimes a reactor emits a louder hum before failing. If you notice a new, steady buzz from the condenser unit, mention it. That sound can point the technician straight to the reactor or its terminals.
Is it worth repairing CH27?
In most cases, yes. A board or reactor replacement restores the system without touching the refrigerant circuit or compressor. On very old systems with other worn parts, it may be worth comparing repair with replacement. The technician should lay out both options. Our LG AC repair cost Sydney page explains general cost factors.
What details help the technician?
Share the model number from the indoor head label, when CH27 first appeared, any storms or outages beforehand, whether breakers tripped and whether you heard buzzing. Mention if other codes such as CH21 or CH23 have also shown.
How can you stay comfortable meanwhile?
The system will not run with CH27, so leave it off. Use fans, blinds and water in summer, or a safe portable heater in winter.
How can you reduce the chance of PFC faults?
- Keep the condenser unit shaded without restricting airflow.
- Keep the outdoor coil and surroundings clean.
- Seal gaps where insects could enter the cabinet.
- Consider surge protection advice from a licensed electrician.
- Book regular servicing so a technician can inspect the board area.
Does CH27 appear more on certain systems?
Larger capacity condenser units and multi split systems draw more current, so their PFC stages handle more energy. They can be slightly more prone to heat related ageing, particularly in hot western suburbs. Keeping these units clean and well ventilated matters even more.
Why does a technician measure under load?
Some PFC faults hide when the compressor is off and only appear once current flows. A transistor might test fine with a meter yet break down under heat and voltage. By monitoring input current and DC link voltage while the system runs, the technician sees how the stage behaves in real conditions. That approach catches faults that a static test might miss.
What happens inside the PFC stage every second?
Household power alternates direction fifty times every second in Australia. Without correction, an inverter would only draw current at the very peaks of each wave, in short, heavy gulps. The PFC stage changes that. Its transistor switches on and off at a very high rate, storing energy in the inductor and releasing it into the DC link in a controlled way. Control electronics adjust the timing constantly so the current drawn follows the shape of the voltage wave.
That precise timing is what makes the stage vulnerable. If the transistor switches late, the inductor saturates or a sensing signal drifts, current can spike within an instant. The board sees the spike, decides it is unsafe and stops everything, which is when CH27 appears.
Why might CH27 appear only occasionally?
An intermittent PFC fault often points to a component on the edge of failure or a connection that loosens with heat. On a cool morning, everything works. By mid afternoon, the cabinet has warmed, a solder joint has expanded or a terminal has loosened slightly, and the stage misbehaves. Keeping a record of when the code appears, including the time and outdoor temperature, gives the technician a valuable pattern to work with.
Supply disturbances can also cause occasional trips. If your area experiences frequent short outages or voltage fluctuations, the PFC stage may react to them even when healthy. In that case, the code typically clears with a reset and does not return until the next disturbance.
What should you expect after a board replacement?
Once a new outdoor board is fitted, the technician powers up the system, checks the communication with the indoor head and runs the compressor through its range. They watch DC link voltage, input current and compressor behaviour to confirm everything sits within normal limits. Some LG models also need specific settings or switches on the new board set to match the old one, which the technician handles during installation.
After that, the system should behave just as it did before the fault. Ask the technician to note what they replaced on your invoice, since that record helps with any future warranty questions.
Can multiple codes appear together?
Yes. A PFC failure can set off a chain reaction. Low DC link voltage may show as CH23, and stressed compressor drive components may log CH21. Seeing several codes at once can look alarming, yet they often share a single root cause. The technician uses the order and combination of codes to decide where to start.
LG CH27 error, booking help
The LG CH27 error means the power factor correction stage in the condenser unit is not behaving. A technician can test the supply, reactor and board safely and restore stable power to the compressor drive.
Many small faults give early warning signs long before a full breakdown.
Choosing a sensible set point eases the load on the compressor through the season.
Closing blinds on sunny windows helps any air conditioner keep up on hot afternoons.
A quick rinse of the mesh screens takes only minutes and improves airflow straight away.
Sharing the location of the isolator switch helps the technician work safely.
Any burning smell is a reason to switch off at the isolator and call straight away.
Small details often make the difference between a quick fix and a second visit.
Call 02 9071 1142 or use our booking page to arrange an LG technician.
Frequently asked questions
What does CH27 mean on an LG?
It generally indicates a fault in the power factor correction stage of the outdoor board.
Is CH27 related to CH23?
Often. A PFC fault can pull the DC link voltage down.
Can a storm cause CH27?
Yes. Surges often damage the input and PFC stage.
Why is my outdoor unit buzzing?
A failing reactor or PFC component can buzz before the code appears.
Can I reset CH27 myself?
One power cycle is fine. If the code returns, book a technician.
Does CH27 need a new compressor?
Rarely. Board, reactor and supply faults are typical.