LG CH44 Error, The Outdoor Air Probe Has Lost Its Way
Your LG needs to know how hot or cold it is outside before it can plan its work.
A small probe mounted on the condenser unit supplies that number. If the reading becomes impossible, the outdoor board stops and the LG CH44 error appears on the indoor display. Here is a straightforward look at what the probe does, why it fails and what a technician does about it.
What does the LG CH44 error mean?
LG service literature generally lists CH44 as an outdoor air temperature sensor fault. The sensor is a thermistor, usually mounted on a small bracket behind the condenser coil, where it can sample the air drawn into the unit. The outdoor board reads its resistance and converts it into a temperature. Should that value land somewhere impossible, the board treats the circuit as open or shorted and raises CH44.
Without this reading, the board loses one of its main reference points for planning compressor speed, fan speed and defrost timing, so LG chooses to stop rather than guess.
How does the outdoor reading guide the system?
The outdoor temperature shapes many decisions behind the scenes. Consider a few examples.
| Decision | How outdoor temperature helps |
|---|---|
| Compressor speed limits | Sets safe operating ranges for hot and cold conditions |
| Outdoor fan speed | Adjusts airflow to suit the weather |
| Defrost timing | Helps judge when frost is likely on the coil |
| Expansion valve position | Feeds into calculations for refrigerant flow |
| Protection logic | Supports high and low pressure safeguards |
A probe that drifts without failing can therefore cause subtle comfort problems, such as defrost cycles at odd times or weaker output in extreme weather.
Where is the probe and why is it exposed?
The outdoor air sensor needs to read the real outdoor temperature, so it sits in the airflow at the back or side of the condenser unit, often clipped near the coil. That location gives an accurate reading but also exposes the probe and its lead to sun, rain, salt, dust and wildlife. Over years, that exposure takes a toll, which is why outdoor sensors fail more often than many indoor ones.
Which symptoms appear with CH44?
The code is the main sign, yet a few clues often appear before or alongside it.
- The system stops completely and the indoor display shows CH44.
- Heating behaves strangely in winter, with frequent or skipped defrost cycles.
- The condenser fan runs at unusual speeds for the weather.
- The code appears after heavy rain, a storm or garden work.
- You notice damaged cables or pest activity around the condenser unit.
- The fault clears for a while and then returns.
Write down any patterns, especially weather related ones.
What usually causes CH44?
Probe failure
Thermistors age with temperature cycling and moisture. Water can seep into the probe body, especially if its protective coating cracks. Eventually, the resistance becomes inaccurate or the circuit opens.
Damaged lead
The sensor lead runs from the probe to the outdoor board, often along the side of the coil. Sunlight hardens its insulation, sharp fin edges cut it and rodents or birds may chew it. A break or short in the lead stops the reading.
Corroded connector
Salt air and humidity attack the plug on the outdoor board. Corrosion increases resistance or breaks contact, distorting the reading.
Probe dislodged
If the probe drops out of its clip and rests against the hot compressor or the sunny cabinet wall, it reads wrong values. Depending on how far off the reading is, the result might be poor control or a full CH44 fault.
Board input fault
Occasionally the reading circuit on the outdoor board fails while the probe itself remains healthy.
What can you safely check?
Because the probe sits inside the condenser unit, your options stay limited, yet a few observations help.
- Switch the system off at the remote and at the outdoor isolator.
- Look around the condenser unit for obviously damaged cables or chewed insulation, without touching anything.
- Check for signs of water pooling around or inside the base of the unit.
- Clear leaves and debris from around the cabinet.
- Restore power, wait a few minutes and restart once.
If CH44 returns, leave the system off and book a visit. Our LG reset guide explains the safe restart. Please do not open the condenser unit, since the board and capacitors carry dangerous voltage.
How does a technician confirm a CH44 fault?
The technician isolates power, removes the access panel and locates the outdoor air probe. They check that it sits correctly in its holder, away from heat sources, and inspect the lead along its full length.
Next, they unplug the probe and measure its resistance, comparing it with LG published values for the current outdoor temperature. They often hold a reference thermometer nearby to confirm the expected figure. An open circuit, short or wildly wrong reading confirms a faulty probe.
If the probe tests well, they inspect the connector for corrosion and check the board input, sometimes substituting a known good probe.
Which repairs typically clear CH44?
| Finding | Typical repair |
|---|---|
| Faulty probe | Replace the outdoor air sensor |
| Damaged lead | Repair or replace the lead and protect it |
| Corroded connector | Clean or replace the plug |
| Probe out of position | Refit in its holder, away from heat |
| Faulty board input | Repair or replace the outdoor board |
After the repair, the technician confirms the reading matches the real outdoor temperature and that the system runs normally.
Why does CH44 matter more in winter?
In heating mode, the outdoor coil gets colder than the surrounding air and frost can form. LG uses the outdoor air reading, together with the coil temperature, to judge when frost is likely and when to start defrost. A faulty or drifting probe can cause defrost cycles too often, which interrupts heating, or too rarely, which lets ice build up. Owners often notice heating comfort problems before CH44 finally appears.
Can extreme heat cause false readings?
If the probe sits in direct sunlight or touches a hot metal surface, it may read much higher than the true air temperature. The board might then limit compressor speed or run the fan harder than needed. This usually causes performance quirks rather than a CH44 code, although very extreme readings can trigger the fault. Shade that leaves airflow clear can help condenser units in exposed spots.
How does CH44 relate to CH45?
CH44 concerns the outdoor air sensor, while CH45 relates to the condenser pipe sensor on the outdoor coil. Both sit on the condenser unit, both are thermistors and both can suffer from weather and pests. However, they measure different things and serve different roles. Our LG CH45 error page explains the coil probe.
Are coastal homes more at risk?
Yes. Salt air speeds up corrosion on connectors and probe bodies. Condenser units close to the ocean often show green or white residue on plugs and terminals. Regular servicing and coil washing help, and the technician may suggest protective measures for connectors.
Is CH44 expensive to fix?
Usually not. Outdoor air sensors are modest parts and quick to replace on most models. Costs rise only if the board needs replacement or wiring damage is extensive. Our LG AC repair cost Sydney page explains general cost factors.
What details help the technician?
Share the model number from the indoor head label, when CH44 first appeared, whether it followed rain or storms, and any signs of pests or damaged cables near the condenser unit. Mention heating quirks you noticed in winter.
How can you stay comfortable meanwhile?
Leave the system off once CH44 repeats. Use fans and blinds in summer or a safe portable heater in winter.
How can you protect outdoor sensors?
- Keep the area around the condenser unit clear of plants and debris.
- Deal with rodents and nesting birds promptly.
- Provide shade that keeps direct sun off the cabinet without blocking airflow.
- Book regular servicing, especially near the coast.
Our LG outdoor unit check guide covers what to look for between visits.
What happens if the probe reads too cold?
A probe that reads colder than reality can make the board think conditions are harsher than they are. In heating, it might trigger defrost too often, breaking up the warm air supply. In cooling, it might limit compressor speed unnecessarily on hot days, reducing capacity. These effects can be subtle. Owners often describe them as the system feeling less powerful than it used to, without any code at first.
What happens if the probe reads too hot?
A probe that reads warmer than reality can delay defrost in winter, allowing ice to build on the coil until heating output collapses. In summer, it might push the condenser fan to higher speeds and change compressor limits. Again, the result may be poor comfort or extra noise rather than an immediate fault code.
How do birds and rodents damage outdoor sensors?
Condenser units offer warmth, shelter and a sheltered gap behind the coil. Birds sometimes build nests in that space, and rats or possums explore the cabinet looking for food or bedding. The thin sensor lead makes an easy target. Chewed insulation exposes the conductors, which can short together or corrode, and the reading quickly becomes unreliable.
Nesting material also traps moisture against the probe and connector. During wet weeks, that damp mass keeps the area humid long after rain stops. If you notice twigs, feathers or droppings around the condenser unit, mention them when booking. The technician can remove the debris safely, repair the damage and suggest ways to discourage future visits.
Can a garden hose damage the probe?
Gentle rinsing of the coil is generally fine with power off. However, a strong jet aimed into the back of the condenser unit can force water into the probe holder and connector. Over time, repeated soakings can lead to corrosion. If you rinse the coil yourself, use a soft spray from the outside, avoid aiming directly at the electrical compartment and let everything dry before restoring power. A professional service handles coil cleaning with care for these components.
How does the system cope during the repair wait?
LG designs the system to stop when CH44 appears, because running without a valid outdoor reading could lead to poor defrost control or unsafe operating limits. Some models may allow limited operation in certain modes, but it is wise not to rely on that. Plan to use alternative heating or cooling until the technician visits. Most outdoor sensor repairs are short jobs, so the system usually returns to normal service quickly once the part is on hand.
Does a multi split system react differently?
On a multi split, the outdoor air probe serves every indoor head through the shared condenser unit. A CH44 fault therefore stops all rooms together, and each display may show the code. The diagnosis and repair stay the same, since there is still only one outdoor air probe to test.
LG CH44 error, booking help
The LG CH44 error tells you the condenser unit cannot read outdoor air temperature reliably. A technician can test the probe, lead and connector, replace what has failed and restore proper control.
Noting the outdoor temperature when a fault appears can reveal useful patterns.
An honest explanation of the fault helps you make a confident decision.
Every system behaves a little differently, so local observations matter.
Asking questions during the visit is a great way to learn about your system.
A steady maintenance rhythm is kinder to the equipment than sudden bursts of attention.
Most owners only need a few minutes each month to keep the basics in order.
Call 02 9071 1142 or use our booking page to arrange an LG technician.
Frequently asked questions
What does CH44 mean on an LG?
It generally points to a fault in the outdoor air temperature sensor.
Where is the outdoor air sensor?
Usually clipped near the back or side of the condenser coil.
Can rain cause CH44?
Moisture can damage the probe or corrode its connector.
Does CH44 affect heating?
Yes. Defrost timing relies partly on the outdoor reading.
Is CH44 an expensive repair?
Usually not. The sensor is a modest part.
How is CH44 different from CH45?
CH44 covers outdoor air, while CH45 covers the condenser pipe sensor.